What should we do if there is a problem with the hydraulic pump of the cement block machine
As an important part of the machinery, the hydraulic pump of the cement block machine should be attended to. When there are problems such as no oil output, insufficient oil delivery, pressure not going up, and severe pressure fluctuations, remember not to take it lightly. But what if we lack professional maintenance skills?
If there is a problem that the cement block machine hydraulic pump does not deliver oil, the oil delivery is insufficient, and the pressure does not go up, it is likely that the motor is turned incorrectly or the suction pipe filter is blocked, or the axial or radial clearance is too large, The viscosity of the mixed air oil is too high, you can check the motor steering, pipeline, clean the filter, change the oil, check and replace the relevant parts, tighten the screws at each connection to avoid leakage and prevent air mixing.
If there is severe noise from the hydraulic pump of the cement block machine and severe pressure fluctuations, it may be due to blockage of the suction pipe and filter or small filter capacity, air leakage at the suction pipe seal, air bubbles in the oil, misalignment of the pump and coupling, and oil temperature low, high viscosity, pump bearings damaged, you can clean the filter to make the suction pipe unobstructed, correctly select the filter, and add some oil to the connection or the sealing to deal with such problems.
Block machine hydraulic pump common problems and solutions on the introduced here, the site will offer occasional cement block making machine conservation knowledge, so stay tuned!